Fundamental TechnologiesGalileo Spacecraft Pages |
Transition Mode Commands


Table 14. EPD Command Functions
| Command | OPCODE | Old Function | ROM-based Default | New Function |
| F0 | Set LSB of Lower Checksum | 00H | Spare | 00-FFH |
| F1 | Set MSB of Lower Checksum Set High Voltage Command Limit (must be <1FH) | 00H | 00-0FH | |
| F2 | Set LSB of Upper Checksum | FFH | Set Subcom Control | |
| F3 | Set MSB of Upper Checksum Set High Voltage Command Level (must be <1FH) | |||
| FC | Set High Voltage Command Limit | Spare | ||
| FD | Set High Voltage Command Level | Spare |