Fundamental Technologies

Galileo Spacecraft Pages

Mechanical System Overview (continued)

With the exception of the LM124, the EPD Radiation Analysis in Table 2 has been submitted to JPL. JPL will run a computer simulation to determine what the estimated radiation dose will be for the parts and points of interest (POIs) shown in Table 2.

TABLE 2. EPD RADIATION ANALYSIS

SubsystemPart Type
Data System1802, mP
Data SystemTCC244, RAM
Data SystemTCC244, RAM
Data System1834, ROM
Motor Control1802, mP
Motor ControlTCC244, RAM
PHAAD571, A-D Converter
PHA1834, ROM
CMS ElectronicsLog Amplifier
CMS ElectronicsDiscrim
LEMMS IDiscrim (2N3251)
LEMMS IDiscrim (2N3251)
LEMMS IIDiscrim (2N3251)
LEMMS IIDiscrim (2N3251)
LEMMS IIDiscrim (2N3251)
LEMMS IIIDiscrim (2N3251)
LEMMS IIIDiscrim (2N3251)
CMS Rate LogicAccumulator
CMS Rate LogicAccumulator
LEMMS Rate LogicAccumulator
LEMMS Rate LogicAccumulator
Bus AdapterAccumulator
ATC 12N2219
ATC 22N2219
ATC 32N2219
ATC 42N2219
LEMMS TelescopePOI
LEMMS TelescopePOI
CMS Electronics (TOF)POI
CMS Electronics (Filter)POI
Axis of RotationPOI
ATC 1-4LM124

The preliminary radiation analysis for the experiment is shown in Table 3. This analysis was completed ten months ago. The dosages shown were calculated by a computer simulation. Some of the device locations have since changed.

TABLE 3. PRELIMINARY RADIATION ANALYSIS

Detector PointPart, Location DOSE (k Rad)
11802, Data System77.2
2RAM and ROM, Data System 75.8
3Misc., Data System106
4Misc., Data System 81.6
51802, Motor Control 73.5
6TCC244, Motor Control 94.2
7AD571, PHA54.9
81834, PHA38.1
9Log Amp, CMS Analog 85.3
10Discrim., CMS Analog 87.6
11Misc., Rotating Section 114
12Misc., Rotating Section 72.1

Table 4 shows a summary of the radiation dosages that some of the parts in the instrument are capable of withstanding. If the dosage levels for the parts are exceeded in the JPL simulation, spot shielding will be installed.

TABLE 4. PARTS CAPABILITY SUMMARY

CD4000 Series400 K rad
CDP1802200 K rad
CDP1834200 K rad
CDP1852200 K rad
TCC244K200 K rad
APL DiscriminatorTBD
MPAe DiscriminatorTBD
Accumulator300 K rad
Log AmplifierTBD
2N2219TBD
AD57175 K rad
LM124TBD

Dr. Studemann commented that the hybrids and the transistors in the voltage switching portion of the electronics are being tested. At least five of each type of part are being tested. Ted Mueller commented that only the discriminators for the LEMMS electronics have been investigated by JPL.

Our estimate of the EPD masses is shown in Table 5. The estimate shows the change in mass between the present estimate and the previous estimate. This is a summary of previously published numbers, rather than a comprehensive review of the instrument itself. The latest estimate shows an increase of 94 grams. The latest calculations for the protective cover show that it is heavier than expected, and the pottings and coatings increased in weight because of a different coating technique.

TABLE 5. EPD MASS ESTIMATE

Subsystem Present
Estimate
Previous
Estimate
Delta
LEMMS Telescope Assembly
   Telescope with MMP
   Preamps and Housing
   Thermal Control

894a,150c

25e

754a,157c,30c
44a,100e
25e

-41
CMS Telescope Assembly
   Telescope with MMP
   Thermal Control

310a,14c
20e

290a,29e
20e

+5
CMS Electronics Assembly
   TOF
   Analog Filters
   Shield
   Housing

370c
177c
20c
233c

370c
177c
20c
233c
 
Telescope Support50c50c  
Motor Assembly
   Motor
   Polytwist
   Encoder

757a
250c
12a,55c

757a
250c
70c



-3
Motherboard Assembly267c 267c 
CMS Analog Electronics65a,152c 65a,143c+9
CMS Rate Logic116a,61c 116a,61c 
LEMMS I147c 167e-20
LEMMS II158a 173e-15
LEMMS III149e 172e-23
LEMMS Rate Logic103a,61c 103a,61c 
Motor Driver550a 550a 
Motor Control133c,18c 113a,18c 
Pulse Height Analyzer148c 148c 
Data System360c 360c 
Bus Adapter133c 133c 
Calibrator/Housekeeping125c 125c 
Power Supply348a 348a 
Protective Cover and Actuators270c 150e+120
Thermal Blanket232c 230c+2
Potting and Coatings152c,48e 130e+70
Frame691c 691c 
Cover612c 600c+12
Passive Shield60c 60c 
P.C. Mounting Bolts68c 65c+3
Hardware30e 30e 
TOTAL8594 8475+119
   Liens Counterbalance 65c
AD571 rad shield 33c
TOTAL Including Liens:  8687 grams

 

MASSPERCENT GRAMS
Actual43.13742
Calculated55.64827
Estimated1.3123

Next: CMS Subsystem

Return to Galileo EPD Handbook Table of Contents Page.
Return to Fundamental Technologies Main Galileo Page.
Return to Fundamental Technologies Home Page.

Updated 2/23/04, T. Hunt-Ward
tizby@ftecs.com