Scanning System Telemetry:

Closed-Loop Mode (Open Loop = 0)

Telemetry (TM) Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Byte 1 Scan Error* Aborted Fast Scan* Emergency Count* *Direction *Centerline

*                       *                    *
Position Code (XYZ)

Byte 2 Emergency Open Loop = 0 Modified Scan Fast Scan Go to Sec-tor "XYZ" X Y Z
Byte 3 Alternate Step Rate

CCW End-Sector Code

Chicken Mode

CW End-Sector Code

Byte 4

 Number of Invalid Motor Commands

Byte 5 Spare Spare

Step Count

Cease Scan*

Open-Loop Mode (Open Loop = 1)

Byte 1 Scan Error* Aborted Fast Scan* Emergency Count* *Direction *Centerline

*               *              *
Position Code (XYZ)

Byte 2 Emergency Open Loop = 1 Limited Scan Fast Scan Respond to "XYZ" Triggers X Y Z
Byte 3 Alternate Step Rate

Not Used

Byte 4

Number of Invalid Motor Commands

Byte 5 Spare Spare

Step Count

Cease Scan*

*These bits are assumed to be sampled every 4/3 second. All other bits may be sampled once a minute.