Scanning System Telemetry:
|
Closed-Loop Mode (Open Loop = 0) |
||||||||
| Telemetry (TM) Byte | Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
| Byte 1 | Scan Error* | Aborted Fast Scan* | Emergency Count* | *Direction | *Centerline |
*
*
* |
||
| Byte 2 | Emergency | Open Loop = 0 | Modified Scan | Fast Scan | Go to Sec-tor "XYZ" | X | Y | Z |
| Byte 3 | Alternate Step Rate |
CCW End-Sector Code |
Chicken Mode |
CW End-Sector Code |
||||
| Byte 4 |
Number of Invalid Motor Commands |
|||||||
| Byte 5 | Spare | Spare |
Step Count |
Cease Scan* | ||||
|
Open-Loop Mode (Open Loop = 1) |
||||||||
| Byte 1 | Scan Error* | Aborted Fast Scan* | Emergency Count* | *Direction | *Centerline |
*
*
* |
||
| Byte 2 | Emergency | Open Loop = 1 | Limited Scan | Fast Scan | Respond to "XYZ" Triggers | X | Y | Z |
| Byte 3 | Alternate Step Rate |
Not Used |
||||||
| Byte 4 |
Number of Invalid Motor Commands |
|||||||
| Byte 5 | Spare | Spare |
Step Count |
Cease Scan* | ||||
*These bits are assumed to be sampled every 4/3 second. All other bits may be sampled once a minute.